Description
This is a simple-to-use compressed natural gas(CNG) sensor, suitable for sensing natural gas (composed of mostly Methane [CH4]) concentrations in the air. The MQ-4 can detect natural gas concentrations anywhere from 200 to 10000ppm.
Technical Specification:
- Power requirements: VCC - 5V±0.1
- DO output: TTL digital 0 and 1 (0.1 and 5V)
- AO output: 0.1-0 .3 V (relative to pollution), the maximum concentration of a voltage of about 4V
- Detection Gas: Natural gas/Methane
- Detection Concentration: 200-10000ppm (Natural gas / Methane)
- Interface: 1 TTL compatible input (HSW), 1 TTL compatible output (ALR)
- Heater consumption: less than 750mw
- Operating temperature: 14 to 122 °F (-10 to 50°C)
Features:
- Good sensitivity to Combustible gas in wide range
- High sensitivity to CH4, Natural gas
- Small sensitivity to alcohol, smoke
- Fast response Stable and long life
- Simple drive circuit
Applications:
- Used in gas leakage detecting equipment for homes and industry. They are suitable for detecting of CH4and CNG
- Industrial Combustible gas detector
- Portable gas detectors